Hybrid Sustainable Energy Learning System
(AG102)
  • Setting up PV systems and testing the optimum alignment of solar modules.
  • Recording and displaying the characteristics of solar modules.
  • Investigating the module′s response to shadow formation.
  • Design and testing of a standalone PV system for the generation of AC voltage compatible with
  • the standard electrical supply.
  • Design and testing of PV systems with mains feed.
  • Investigate response of a PV system to mains failure.
  • Drawing The I-V Curve of PV Panel.
  • Measuring the Power of a Solar PV Panel.
  • Effect of Light Intensity on PV Panel.
  • Investigating with different daily irradiation periods.
  • Effect of Temperature on PV panel.
  • Understanding the design and operation of modern small wind power stations.
  • Explore the physical fundamental from wind energy into electricity.
  • Design & operation of wind power station with energy storage system.
  • Design & operation of OFF-grid wind power station.
  • Operation of isolated wind power station and the effect of wind fluctuation on the operation.
  • Studying the effect of changing wind speed.
  • Examination of Hydrogen Fuel Cell Output Voltage with Oscilloscope.
  • Examination of Hydrogen Fuel Cell Output Voltage Under Load with Oscilloscope.
  • Examination of Output Voltage from Hydrogen Fuel Cell DC/DC Converter using an oscilloscope.
  • Examination of Output Voltage from Hydrogen Fuel Cell DC/DC Converter using an oscilloscope.
  • Analyzing & Comparing Battery & Fuel Cell Model.
  • Appling Fuel Cell Technology.
  • Familiarization with battery- Fuel Cell Hybrids.
  • Wind Emulator Code: (AG102.02):
    • Three-phase motor
      • 3 HP
      • Speed: 900 rpm
    • Synchronous Generator Plant with Permanent Magnets
      • Generator type: 3-Phase permanent magnet synchronous generator
      • Voltage with no load: 30 V
      • Nominal current: 25 A
      • Nominal speed: 1000 rpm
      • Nominal power: 0.75 kw
    • Speed Meter
      • Digital Rotor Speed: 0…9999 RPM
      • RS-485 communication supported with ability to pc connection through remote control module.
    • Energy Monitor
      • Three-phase measurement of current and voltage: 3x400 V/5 A
      • Two Digital inputs
        • Working Voltage: 24V
      • Max. measurement values
        • Voltage P-P: 690 V
    • Current: 5 A
      • Fault tolerances
        • Voltage 0.2%, Current 0.2%
        • Apparent power 0.5%, Active power 0.2%, Reactive power 1%
        • Active energy Class 0.2, Reactive energy Class 2
      • Operating voltage
        • 110 V-230 V, 50/60 Hz
  • Load Modules (AG102.03.01):
    • Resistor Value Range: 0…800-ohm, 0….150-ohm, 0…100-ohm.
    • Power: 500 W.
  • PWM Solar Charge Controller (AG102.03.02)
    • Voltage: 12V/24V Auto
    • Voltage: 12V/24V Auto
    • Current: 30A
    • Max.PV input voltage: 100V
    • Max PV input power: 400W/12V, 8000 W/24V
  • Solar Accumulator (Battery) (AG102.03.04):
    • Battery Voltage: 24V
    • Battery Capacity: 9 A/H
  • DC Load (AG102.03.05)
    • Halogen Lamp
      • Voltage Required: 12V
      • Watt: 50 W
    • LED Lamp
      • Voltage Required: 12V
      • Watt: 4 W
  • DC Network Meter (AG102.03.06)
    • Digital Voltameter: 600 vdc peak
    • Digital ammeter: 25 A DC peak
    • Modbus through RS-485
  • PWM Charge Controller (AG102.03.07):
    • Rated PV current 35 A
    • Charging / load current @ 25°C (77°F) 35 A
    • Voltage configurations 12 and 24 V
    • Max. PV open circuit array voltage 55 V
    • Max. voltage drop through controller 0.30 V
    • Total operating consumption 15 mA
  • Fuell Cell (AG102.04)
    • Fuel Cell System:
      • Rated output: 1200 W @ 5 ... 25 °C
      • Rated current: 60 ADC max.
      • Operating voltage: 18 ... 36 VDC
      • Maximum hydrogen consumption: 15 Nl/min
      • Hydrogen purity for operation: min. 4.0
      • Permissible H2 inlet pressure: 1 … 15 bar
    • H2 Flow Meter:
      • Measuring range: 0.83 … 25 Nl/min.
      • Measuring accuracy: ± 1.5 % from the end value.
    • H2 Sensor:
      • Sensor standard range: 0.00 … 1.00 Vol. % H2.
    • DC Converter with Integrated Load Regulator:
      • Max. output power: 1500 W
      • Max. output current: 55 ADC
      • Rated output voltage: 24 VDC
      • Output voltage range: 21 … 30 VDC
      • Max. input current: 60 ADC
      • Input voltage range: 18 … 36 VDC
      • Efficiency: 96 %
    • Inverter:
      • Continuous output power: 1500 WAC.
      • Inlet voltage: 21 … 30 VDC.
      • Output voltage 230 VAC (50 Hz), 115 VAC (60Hz).
      • Output signal form pure: Reiner Sinus (THD < 3 %).
      • Efficiency: 91/93 % (110/230 V).
    • Electronic Load Module:
      • Max. continuous power: 1200 W.
      • DC load current: 0 … 85 ADC.
      • DC load voltage: 0 … 80 VDC.
      • Load resistance: 0.08...30 ΩC.
    • Battery Module:
      • Battery set 1: lead-acid, 24 V, (2 x 12 V), 7,2 Ah.
      • Battery set 2: lead-acid, 24 V, (2 x 12 V), 18 Ah.
      • Safety elements: 30 A, 80 A.
    • H2 Storage Module:
      • Hydrogen manometer: 0 … 25 bars
      • Safety elements: 3 x temperature sensors, pressure relief valve, hydrogen safety switch, manometer.
  • Hybrid Sustainable Energy Learning System (AG102)
    • Main frame (AG102.01)
    • 1x Wind Emulator (AG102.02)
    • 1x DC Kit (AG102.03)
    • 1x Load Modules (AG102.03.01)
    • PWM Solar Charge Controller (AG102.03.02)
    • MPPT Solar / Wind Charge Controller (AG102.03.03)
    • 1x Solar Accumulator (Battery) (AG102.03.04)
    • 1x DC Load (AG102.03.05)
    • Digital meters Module (AG102.03.06)
    • Hybrid Charge Controller (AG102.03.07)
    • 3-phase Rectifier Module (AG102.03.08)
    • Blocking & By-pass Diode Module (AG102.03.09)
    • Fuel Cell (AG102.04)
    • Software (AG102.05)
  • 3X PV Solar Panel (RE101)
  • Hard copy user manual
  • Digital content (BI01)
  • Storage Unit (BI03)
  • PV Solar Panel (Extra)(RE101)
  • OFF-Grid Inverter (RE102)
  • ON-Grid Inverter (RE103)
  • PV Emulator Power Supply (RE104)
  • PV Power Planet (RE105)
  • Wind Turbines planet (RE107)
  • Advanced Wind Energy Emulator Training System (RE108)
  • AC Kit (RE111)
  • Laboratory PC.

Hybrid Sustainable Energy Learning System combined with a fuel cell is designed to demonstrate trainees on sustainable energy technologies by integrating solar, wind, and hydrogen fuel systems. Its main features include hybrid energy integration, monitoring, and hands-on learning modules, all supported by an intuitive user interface. Using this training system, trainees will get familiarized with electricity generation from solar energy as well as wind energy, and the applications associated to these processes. By mixing and matching the provided modules, trainees will be able to execute a wide range of experiments. Whether, there’s an available sunlight source/ wind source or not, trainees would still be able to carry out the same experiments using provided emulators. The system’s specifications outline its capacity for energy generation, hydrogen production rates, advanced control systems, and compliance with safety standards, ensuring a comprehensive educational experience in renewable energy solutions.

  • Main Frame Code: (AG102.01)
    • The training system comprises a main frame panel where all of the provided modules can be mounted to it.
    • The frame is designed in the form of modular system which allows trainees to alter the experiment conditions upon changing the used modules. The frame consists of three horizontal rows for mounting modules.
    • The main frame is a single-phase power supply unit with neutral and line paths needed for the power supplying and connection with the experimental modules
    • Up to 9 modules can be mounted at the same time which gives students the opportunity to execute more complex and sophisticated experiments.
    • The frame is supplied with a metal Bench where students can put any needed tool or measuring device for an easy access.
    • The frame is equipped with external cable holders to hang the training system cables.
    • The frame is electrostatically painted and assembled using special accessories to provide more durability and prevent corrosion.
    • The main frame is supplied with ON/OFF switch, emergency button, circuit breaker and two extra power sockets required for the connection of any external devices.
  • Wind Emulator Code: (AG102.02)
    • The educational unit consists of a wind energy emulator and a control unit to display and control the speed of wind in order to simulate a real-life scenario of wind generation and to determine the performance of a wind power plant.
    • The control unit is capable of adjusting the speed of wind and displaying the measured wind, rotor speed, voltage and current values.
    • The module is supplied with run/stop switch to run the motor; a speed control potentiometer is supplied to change speed of the motor.
    • Shaft speed can be displayed and monitored through a mounted display.
    • The system is supplied with motor protection switch needed for obtaining the output.
    • The wind emulator is supplied with emergency button, operation indication LED, main ON/OFF switch, circuit breaker as well as overload indication LED
  • DC Kit (AG102.03)
    • Load Modules (AG102.03.01)
      • This module is designed to allow students to add loads to any experiment.
      • This load can be connected to another load modules in series or in parallel which provides students with variety of load values for experiments.
  • PWM Solar Charge Controller (AG102.03.02)
    • This module ensures a steady voltage is supplied from a system, resulting in optimal battery maintenance.
    • The unit also features a large LCD display that informs the user about the state of charge and operating modes. Additionally, the unit also features a user-controlled energy meter.
  • MPPT Solar / Wind Charge Controller (AG102.03.03)
    • This Module controller is advanced maximum power point tracking (MPPT) charging technology for off-grid photovoltaic systems. it is mainly used in the field of security monitoring, RV, and household system, etc.
    • Solar Accumulator (Battery) (AG102.03.04)
    • This Module is designed to enable students to charge and discharge batteries according to the experiment needs.
    • The module also obtains the ability to connect Remotely, so that students can connect and disconnect this module remotely through our software.
  • DC Load (AG102.03.05)
    • This Module is designed to simulate a real DC Load, using two different types of lamps.
    • The module consists of two Halogen lamp and two LED lamps.
    • This module enables students to access different load wattage on experiment.
  • DC Network Meter (AG102.03.06)
    • Digital Current Meter:
      • Two independent Channel.
      • Each channel has two Ranges (5A peak Range – Accuracy +-1% / 10A peak Range – Accuracy +-1%).
      • Channels protected against over current.
    • Digital Voltage Meter:
      • Two independent Channels.
      • Each channel has a selectable Range of (60V peak Range – Accuracy +-1% / 300V peak Range – Accuracy +-1% / 600V peak Range – Accuracy +-1%).
      • Channels protected against over voltage.
    • Communication:
      • RS485
    • Graphical Display:
      • Touch LCD 5inch, 800x480 pixel display
      • Monitoring 2 voltage channels and 2 current channels,
      • Configuring Measurement Ranges
    • Power Supply: 220V AC 50/60 Hz 0.3A
  • PWM Charge Controller (AG102.03.07)
    • This Module controller is a 30-amp multi-function DC controller that is field configurable for both 24v or 48v operation. The DC controller is a critical component in any solar, wind or hydro power generation system and protects the batteries from over-discharge and over-charge conditions.
      • Fan array maximum open circuit voltage (V): 51
  • 3-phase Rectifier Module (AG102.03.08)
    • This module is used to convert three-phase alternating current to direct current. It has three inputs terminals for AC voltage and two output terminals for DC voltage.
    • Blocking & By-pass Diode Module (AG102.03.09)
    • Bypass diodes are wired in parallel with individual solar cells or panels to provide a current path around them in the event that a cell or a panel becomes faulty or open circuit.
    • Blocking diodes allows the flow of current from a solar panel to the battery but prevents or blocks the flow of current from battery to solar panel, thereby, preventing battery from discharge
  • Fuell Cell: (AG102.04)
    • The Fuel Cell Training system is an ideal tool for teaching PEM fuel cell systems' basic engineering fundamentals.
    • The Fuel Cell-Battery Hybrid System that lets trainees’ study and comprehend different hybrid configurations and system behavior.
    • Trainees can investigate the future of energy technology on a strong platform made available by the Integrated Training System.
  • Software Code:(AG102.05)
    • The system is supplied with software where all of the measured values can be displayed and monitored.
    • Through the supplied software, trainees will be also able to plot all of the related curves.