We Make The Difference
Air-Conditioning Model
(AR - 002)

1 Air duct. 2 Humidifier. 3 Outlet quick connection. 4 Inlet quick connection. 5 Evaporator. 6 Expansion valve. 7 Preheater. 8 Reheater. 9 Blower. 10 Humidity and temperature sensor. 11 Fresh air inlet. 12 Air damper. 13 Air outlet. 14 Flow sensor. 15 Inlet solenoid valve. 16 Outlet solenoid valve. 17 Refrigerant filling valve

  • Operation Experiment
    • Cooling Process
    • Heating Process
    • Humidification Process
    • Dehumidification Process
    • Cooling with Humidification Process
    • Cooling with Dehumidification Process
    • Heating With Dehumidification Process
    • Faults Simulation Experiments
    • Delivery Pipe at the Compressor Clogged
    • Intake Pipe at the Compressor Clogged
    • Condenser Fan Fault
    • Expansion Valve Fault
    • Evaporator Fault
    • Heating with Humidification Process
  • Air duct.
  • Humidifier.
    • Power Supply: 220 – 230 V, 50/60 Hz.
    • Water capacity: 2 liter.
    • Steam pressure: 2.5 bar.
    • Boiling electric power: 1000 W.
  •  Expansion valve
    • Body material: Brass
    • Capillary tube length [in]: 59 in
    • Capillary tube length [mm]: 1500 mm
    • Factory setting (FS) [°C]: 6 °C
    • Flow direction: Single-flow
    • Max. Working Pressure [bar]: 34 bar
    • Static Superheat (SS) [°C]: 4 °C
    • Static Superheat (SS) [°F]: 7.2 °F
    • Temperature range [°C] [Max]: 10 °C
    • Temperature range [°C] [Min]: -40 °C
  • Heaters: 800 W.
  • Blower.
    • Air flow: 400 m3/h.
    • Power: 0.09 KW.
    • Voltage: 220V.
    • Pressure: 340 Pa.
    • RPM: 2800 r/min.
    • Frequency: 50 Hz.
  •  Humidity and temperature sensor.
    • Measuring Range: 10 to 95% RH., -40 to 60°C.
    • Temperature sensor: pt100.
    • Accuracy: ± 2.5% RH, ± 0.3°C.
    • Analogue outputs: 0-10V or 4-20 mA.
    • Supply: 24V AC/ DC.
  •  Solenoid valve.
    • Ambient temperature range [°C] [Max]: 80°C.
  • Frequency [Hz]: 50 Hz.
  • Ambient temperature range [°C] [Min]: -40°C.
  • Power consumption: 12 W.
  • Rel. Humidity [% RH] [Max]: 100 %.
  • Rel. Humidity [% RH] [Min]: 0 %.
  • Supply voltage: 220 V.
  • Air-Conditioning Model - (AR - 002)
  • Hard copy user manual

The air conditioning model (AR – 002) is a part of the Refrigeration and Air Conditioning Training System. By connecting the model to the base unit electrically and hydraulically, a complete refrigeration circuit is created to simulate a full air conditioning system.

  • This model demonstrates the principles and components of a full air conditioning system.
  • This model introduces the operation of an air conditioning system and the recirculating air and outer air operating modes.
  • The room climate is created by the interaction of air temperature, heating temperature and air humidity.
  • The model includes two air ducts with transparent front.
  • The top air duct serves as climatic chamber whilst the bottom air duct contains the air cooler, two electric air heaters and a steam humidifier the air in the duct system can be cooled, heated, humidified or dehumidified.
  • The individual system components are operated via the software.
  • Temperature and humidity before and after the evaporator and in the climatic chamber are recorded by sensors, digitized and represented dynamically in the software.
  • The conditioning of the air can be monitored in the h-x diagram.
  • The model is connected to the base unit electrically by data cables and hydraulically by refrigerant hoses.