Pneumatics & Electro Pneumatics Training System
(CT-008)

1.Control Panel , 2.Operation Panel , 3.Air compressor , 4.Drawers Unit , 5.Aluminum grooved panel, 6.Expirmental Component , 7.Air Manifold

  • Understanding the usage of Relays in Pneumatic circuits.
  • Understanding the usage of timers in Pneumatic circuits.
  • Understanding the usage of selectors in Pneumatic circuits.
  • Understanding the usage of push button in Pneumatic circuits.
  • The trainer can also perform the following experiments based on the options selected.
  • Pneumatic and electro-pneumatic training system (CT-008)
    • Main frame (CT – 008.01)
    • Pneumatic unit (CT-008.02)
    • Control panel (CT-008.03)
    • Experimental Main kit (CT-008.04)
  • Hard copy user manual

The pneumatic & electro-pneumatic training system is designed to provide a practical training on a wide range of pneumatic & electro-pneumatic circuits used in most common industrial applications. The training system is equipped with a large number of components to enhance students’ skills on constructing circuits and reading the related schemes and drawings. Using this training system enables students to learn how to integrate different components in the circuit as well as to carry out the wiring of various electrical components to operate the circuit.

                                     
  • The trainer consists of a main frame, control panel, and a main experimental kit.
  • It also has four optional kits (Not Included), where you can choose from to constructing and control different pneumatic & electro-pneumatic circuits 
  • The modules are interchangeable to provide trainees the ability of mixing and matching them based on the experiments to be carried out.
  • Main Frame (CT - 008.1)
    • The main frame mainly comprises a mobile double-sided chassis, operation panel, pneumatic system, and drawers’ unit.
    • The mobile double-sided chassis is made of aluminum profile with central grooved plate on each side for components fixation.
    • The drawers’ unit creates a space-saving storage for a variety of workpieces.
    • The trainer is supplied with a holder for cables on both right and left sides of the trainer.
    • Operation Panel
      • The operation panel of the system is found on the upper side of the training system.
      • This operation panel includes main trainer ON/OFF switch, power supply indication LED, emergency button, air compressor ON/OFF switch, main circuit breaker for protection, and overload indication LED
  • Pneumatic system is applied to the system through a provided air compressor and air reservoir at the lower cabin of the trainer.
  • The educational unit is also provided with Air service unit (filter-regulator-lubricator (FRL) assembly) to purify compressed air
  • The unit is supplied with air manifold to distribute air at the various parts of the pneumatic circuits.
  • Air compressor
    • Capacity: 24 L
    • Pressure: 8 bar
  • Compressor silencer
    • Air-distributor
  • Each side of the educational unit is equipped with a control panel that includes different modules for classic control components, power supplies, indication lamps and digital displays.
  • The control panel is located at the upper part of the trainer and it consists of 8 different modules as following:
    • Push buttons module
      • The push buttons are used to control the opening and the closing solenoid valves.
      • Input voltage: 220 VAC / 24 VDC
    • » Selectors module
      • The Selectors are used to control the opening and the closing solenoid valves.
      • Input voltage: 220 VAC / 24 VDC
    • Relays module
      • Relays are used to control solenoids by latching.
      • Input voltage: 24 VDC
    • Digital counter
      • The digital counter is provided to count the times of process repetition.
      • High-speed response
      • High display accuracy: ±0.3%
      • AC/DC power: 24VAC 50/60Hz, 24-48VDC
      • Time: 20 ms
    • Timer module
      • Timers are used to control timing of the processes by controlling valves solenoids operation timing.
      • AC/DC power: 24VAC 50/60Hz, 24-48VDC
      • Delay time: 1 – 99 sec
    • LEDs module
      • LEDs are used as indications of the components’ operation and as alarms when a failure occurs.
      • Input voltage: 220 VAC / 24 VDC
    • Buzzer module
      • Buzzers are used as indications of the components’ operation and as alarms when a failure occurs.
      • Input voltage: 220 VAC / 24 VDC
    • Power supply
      • Two lines of 24V outputs used to supply the control panel units.
      • Input voltage: 85 – 265 V AC (47 –63 Hz).
      • Output voltage: 24 V DC, short-circuit-proof.
      • Output current: max. 5 A.
  • Different cylinders are provided in the system such as:
    • Single Acting Cylinder
      • Max. pressure: 10 bar
      • Stroke: 40 mm – 50 mm
    • Double Acting Cylinder
      • Max. pressure: 10 bar
      • Stroke: 100 mm – 120 mm
    • Analog pressure sensor
      • Operating Voltage: 24VDC
      • Operation Range: 0 - 250 bar
    • Inductive sensor
      • Operating Voltage: 24vdc
      • Output: PNP
      • Sensitivity: 18mm
    • Capacitive sensor
      • Operating Voltage: 24vdc
      • Output: PNP
      • Sensitivity: 18mm
    • Optical sensor
    • Proximity sensor, electronic
        • PW:10-30 VDC
        • O/P: 24 VDC/ 150 mA
        • Digital Time Relay Unit
        • Delay time: 1-99 sec
    • Pressure switch, electronic
      • Max pressure: 230 kg/cm2
    • Electrical limit switch left actuated with roller
      • Power consumption: 6A, 250V, AC
      • Power consumption: 0.8A, 125V, DC
    • Electrical limit switch right actuated with roller
      • Power consumption: 6A, 250V, AC
      • Power consumption: 0.8A, 125V, DC