Radio Frequency (RF) Calibration Bench
(MW104)

Table load capacity:

  • Weight loading :200 kg Surface load capacity

Table dimensions:

  • Width: 2000 mm
  • Depth: 900 mm
  • Height: 750 mm
  • Castor diameter 100 mm
  • Height adjustable: Table height adjustable from 750 mm to 1200 mm (option)

Production Digital Multimeter

  • 15 measurement functions, including capacitance, temperature and digitizing.
  • Expanded measurement ranges: 10pA to 10A and 1 mohm to 100 Mohm

Adjustable DC Power Supply

  • DC output rating
    • Channel 1: (0 – 30V), (0 – 3A)
    • Channel 2: (0 – 30V), (0 – 3A)
    • Channel 3: (0 – 5V), (0 – 3A)
  • Maximum power: 195W
  • Load regulation:
    • Voltage: ≤0.02% + 4mV
    • Current: ≤0.2% + 3mA

Variable AC Supply

  • Variable output voltage:
  • 0 to 110 % above line input
  • 0 to 265 V 50 Hz, 10 A at 240 V input
  • 0 to 121 V 50 Hz, 10 A at 110 V input
  • 0 to 10 A output current

Main Power Control

  • ON / OFF Switch
  • Emergency Stop
  • Power ON
  • AC Voltmeter
  • MCB & RCCB
  • Light Switch
  • 2x 220 VAC

Function Generator

  • Max Frequency: 30MHz
  • Channels: 2
  • Sampling Rate: 200MSa/s
  • Waveforms: Sine, square, pulse, ramp, noise, DC, arbitrary
  • Power: DC5V, 2A

Oscilloscope

  • Channels: 2
  • Bandwidth: 200 MHz
  • Sampling rate: 1 GS/s
  • Power source
  • Power source: 100 to 240 VAC RMS ±10%

27 GHz Low Phase Noise Reference Source

  • Highlights
    • “Self-characterization” lets you avoid calculating correction factors for each component in the signal delivery system
    • Covers a broad range of RF calibration workload
    • Reduces the number of instruments and interconnections required for your RF calibration system
    • Integrated 300 MHz frequency counter and dual power meter readout eliminate need for additional instruments
    • Calibration-specific interface simplifies technician tasks
    • Simplifies uncertainty calculations
    • Lowers RF system maintenance costs
    • With automation, reduces spectrum analyzer calibration times by as much as 50 % over manual methods
  • RF calibration devices, including:
    • Spectrum analyzers, including higher frequency models
    • RF power sensors
    • Modulation meters and analyzers
    • Measurement receivers
    • Frequency counters
    • RF attenuators and components
    • High frequency oscilloscopes

Low Phase Noise Reference Source

  • Highlights
    • Covers a broad range of RF calibration workload
    • Reduces the number of instruments and interconnections required for your RF calibration system
    • “What you set is what you get” accurate signal delivery direct to the DUT input
    • Integrated 50 MHz frequency counter eliminates need for an additional instrument
    • Calibration-specific interface simplifies technician tasks
    • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)
    • Lowers RF system maintenance costs
    • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods
  • RF calibration devices, including:
    • Spectrum analyzers
    • Modulation meters and analyzers
    • RF power meters and sensors
    • Frequency counters
    • Attenuators
  • Radio Frequency (RF) Calibration Bench (MW104)
  • Hard copy user manual

The RF (Radio Frequency) Calibration Bench solutions feature modules and auxiliary devices designed for verifying and testing instruments like transmitters, gauges, and switches. The bench consoles can accommodate various equipment, such as power supplies, testers, controllers, and calibrator modules, providing a functional and adaptable environment.

  • Radio frequency calibration laboratory bench offers a compact, adaptable workspace for a range of calibration, test, and measurement applications.
  • The test system is based mainly on the table superstructure section which consists of the worktable with floor cabinet the test & calibrate section including all built-in modules required to operate the system.
  • The system plays an important role in many applications as it is used in many fields such as education, research and development, quality assurance, auditing, and in production.
  • Modern calibrators also frequently output data for a variety of electrical operations, including voltage, resistance, and current.
  • The benches ought to be adaptable enough for testers of diverse heights, levels of ability, and sit-stand preferences to utilize with ease.
  • It incorporates a framework bench with robust steel end frames and cross braces to provide maximum reinforcement.
  • Additional fittings are also available. The standard arms and console are fitted to the heavy-duty frame, with a perforated panel supplied.
  • The trainer included software that through the measured parameters can be displayed and stored.
  • The interactive software that comes with the educational unit is designed to be helpful during experiments, by record readings and making calculations that verify the performance of the testbench.
  • Table Accessories (Optionally)
  • Tool panel
    • Steel structure.
    • Accessories of tool panel:
      • Suspension rails and pick-up boxes.
      • Hook sets
      • Shelf Dividers
      • Plastic Hanging Bins with Hangers
      • Dowel Rod and 4in Shelf Assembly
      • Screwdriver Holders (Holds 6 Each)
      • Hammer Holders
      • Assortment of (22) Additional Hooks and Brackets

Support for instruments

  • Support for various process instruments (pressure transmitters, switches, etc.)
  • Correctly secured instruments make calibration and repair work easier.
  • Includes a plate and a tube bracket to be compatible with standard size devices.

Workbench holders

  • Display brackets & Keyboard tray
  • Document holder & Tablet/ Cellphone holder
    • Profile slot with a strong position, for a variety of common attachment components, including monitor brackets, lamps, and accessories, use the heavy-duty slot.
    • Documents and illustrations can be quickly posted.
    • Two magnets are provided with the document holder.
    • A display that is fixed to a separate holder frees up room on the tabletop.
    • An adjustable display holder enhances work ergonomics.
    • The keyboard tray is secured underneath the tabletop.
    • Steel structure.