We Make The Difference
Hydro-Electric Power Training System
(RE - 010)
  • Studying the basic concepts and operation of hydraulic power conversion into electricity.
  • Discussion of the applications of hydraulic power conversion.
  • Calculation of turbine generator efficiency.
  • Calculation of the inverter efficiency.
  • Studying the effect of water pressure variation on the electric power generated.
  • Studying the effect of applied load variation on the electric power produced by the generator.
  • Hydro-Electric power training system (RE-010)
    • Main Frame (RE-010.1)
    • Hydropower Emulator (RE-010.2)
    • Experimental Modules Kit (RE-010.3)
    • Software (RE-010.4)

The hydro-electric power training system enables trainees to investigate on hydropower plants conversion of the potential or gravitational energy of water first into mechanical and then electrical energy. The educational unit consists of hydroelectric power plant and table top control panel real-life components. The educational trainer is supplied with software system for calculations and display of parameters.

  • Main Frame Code: (RE-010.1)
    • The training system comprises a main frame panel where all of the provided modules can be mounted to it.
    • The frame is designed in the form of modular system which allows trainees to alter the experiment conditions upon changing the used modules. The frame consists of three horizontal rows for mounting modules.
    • The main frame is a single-phase power supply unit with neutral and line paths needed for the power supplying and connection with the experimental modules
    • Up to 9 modules can be mounted at the same time which gives students the opportunity to execute more complex and sophisticated experiments.
    • The frame is supplied with a wooden bench where students can put any needed tool or measuring device for an easy access.
    • The frame is equipped with external cable holders to hang the training system cables.
    • The frame is equipped with fixed holder the computer CPU and another moveable holder for the computer screen.
    • The frame is electrostatically painted and assembled using special accessories to provide more durability and prevent corrosion.
    • The main frame is supplied with ON/OFF switch, emergency button, circuit breaker and two extra power sockets required for the connection of any external devices.
    • It also includes two meters for measuring flow and pressure, pump control unit to control pump operation and speed and plugs which connect the hydropower emulator with the trainer.
  • Hydropower Emulator Code: (RE-010.2)
    • Turbine-generator unit (RE-010.2.1)
    • Stainless-steel submersible sump Pump (RE-010.2.2)
    • Water tank (RE-010.2.3)
    • Flow rate sensor (RE-010.2.4)
    • Pressure sensor (RE-010.2.5)
  • Experimental Modules Kit Code: (RE-010.3)
    • Energy Monitor Module (RE-010.3.1)
    • 3x DC Network Meter (RE-010.3.2)
    • AC Network Meter (RE-010.3.3)
    • MPPT Solar / Wind Charge Controller (RE-010.3.4)
    • Battery Accumulator (RE-010.3.5)
    • 3-phase Rectifier Module (RE-010.3.6)
    • DC Load (RE-010.3.7)
    • Lamp module (RE-010.3.8)
  •  Software Code:(RE-010.4)
    • The system is supplied with software where all of the measured values can be displayed and monitored. All of the modules can also be controlled through the software system.
    • Through the supplied software, trainees will be also able to plot all of the related curves such as V&I curves.
    • all of these software features can be accessed through connecting with the supplied remote module
  • Three-phase measurement of current and voltage: 3x400 V/5 A
    • two Digital inputs
  • Working Voltage: 24V
    • Two relay outputs
  • Operating Voltage: 220 VAC
  • Max Current: 5A
    • Max. measurement values
      • Voltage P-P: 690 V
      • Current: 5 A
    • Fault tolerances
  • Voltage 0.2%, Current 0.2%
  • Apparent power 0.5%, Active power 0.2%, Reactive power 1%
  • Active energy Class 0.2, Reactive energy Class 2
    • Operating voltage
      • 110 V-230 V, 50/60 Hz
  • 3x DC Network Meter (RE-010.3.2)
    • The DC network meter is supplied to monitor dc network power flow in a digital way
    • The module has a digital process indicator used as DC current meter and digital DC voltage meter. It support Modbus communication through RS-485 serial interface.
    • Technical Data
      • Digital Voltammeter: 600 vdc peak measurement
      • Digital ammeter: 25 Adc peak measurement
      • Modbus through RS-485
  • The AC network meter is supplied to monitor dc network power flow in a digital way
  • The module has a digital process indicator used as AC current meter and digital AC voltage meter. it support Modbus communication through RS-485 serial interface.
  • Technical Data
    • Digital Voltammeter: 500 vdc peak measurement
    • Digital ammeter: 20 Adc peak measurement
    • Modbus through RS-485
  • This Module controller is advanced maximum power point tracking (MPPT) charging technology for off-grid photovoltaic systems.it is mainly used in the field of security monitoring, RV, and household system, etc.
  • Technical Data
    • Voltage:12V/24V Auto
    • Current:30A
    • Max.PV input voltage:100V
    • Max. PV input input
      • power:400W/12V,8000W/24V
    • Communication:RS232
  • This Module is designed to enable students to charge and discharge batteries according to the experiment needs.
  • The module also obtains the ability to connect Remotely, so that students can connect and disconnect this module remotely through our software.
  • Technical Data
    • Battery Voltage: 24V
    • Battery Capacity: 50 A/H
  • This module is used to convert three-phase alternating current to direct current. It has three inputs terminals for AC voltage and two output terminals for DC voltage.
  • Technical Data
    • 3 phase Input Voltage: up to 32 V AC
    • 3 phase Input current: up to 20 A AC
    • Rated output power: 1.2 Kw
    • Rated DC voltage output: 0 to 56 V DC
  • This Module is designed to simulate a real DC Load,
  • The module consists of two Halogen lamp
  • Technical Data
    • Halogen Lamp
      • Voltage Required: 12V
      • Watt: 50 W
  • This Module is designed to simulate a real AC Load
  • Technical Data
    • Voltage Required: 220V AC
    • Watt: 100 W