The hydro-electric power training system enables trainees to investigate on hydropower plants conversion of the potential or gravitational energy of water first into mechanical and then electrical energy. The educational unit consists of hydroelectric power plant and table top control panel real-life components. The educational trainer is supplied with software system for calculations and display of parameters.
Main Frame Code: (RE110.01)
- The training system comprises a main frame panel where all of the provided modules can be mounted to it.
- The frame is designed in the form of modular system which allows trainees to alter the experiment conditions upon changing the used modules. The frame consists of three horizontal rows for mounting modules.
- The main frame is a single-phase power supply unit with neutral and line paths needed for the power supplying and connection with the experimental modules
- Up to 9 modules can be mounted at the same time which gives students the opportunity to execute more complex and sophisticated experiments.
- The frame is supplied with a metal bench where students can put any needed tool or measuring device for an easy access.
- The frame is equipped with external cable holders to hang the training system cables.
- The frame is electrostatically painted and assembled using special accessories to provide more durability and prevent corrosion.
- The main frame is supplied with ON/OFF switch, emergency button, circuit breaker and two extra power sockets required for the connection of any external devices.
- It also inculdes metering panel for measuring flow and pressure, it also include pump control unit to control pump operation and speed and pluges which connect the hydropower emulator with the trainer.
Hydropower Emulator Code: (RE110.2)
-
- Turbine-generator unit (RE110.02.01)
- Stainless-steel submersible sump Pump (RE110.02.02)
- Water tank (RE110.02.03)
- Flow rate sensor (RE110.02.04)
- Pressure sensor (RE110.02.05)
Experimental Modules Kit Code: (RE110.03)
-
- Energy Monitor Module (RE110.03.01)
- 3x DC Metering Panel (RE110.03.02)
- MPPT Solar / Wind Charge Controller (RE110.03.03)
- Battery Accumulator (RE110.03.04)
- 3-phase Rectifier Module (RE110.03.05)
- DC Load (RE110.03.06)
- Lamp module (RE110.03.07)
Software Code:(RE110.04)
-
- The system is supplied with software where all of the measured values can be displayed and monitored.
- Through the supplied software, trainees will be also able to plot all of the related curves.
- The Hydropower emulator consists of turbine generator with water distributor, centrifugal pump, water tank, pressure and flowrate sensors.
- Turbine-generator unit (RE110.02.01)
- Aluminum Pelton turbine, d = 200 mm,
- Blade no.= 20
- Permanent magnets synchronous generator
- Nominal electric power output: 0,5 kW
- Generator speed: 500 rpm
- Stainless-steel submersible sump Pump (RE110.02.02)
- Power: 1.5 kW
- Maximum flow rate: 230 L/min
- Maximum head: 30 m
- Water tank (RE110.02.03)
- Flow rate sensor (RE110.02.04)
- Range: 25 - 250 liters/minute
- Pressure sensor (RE110.02.05)
Energy Monitor Module (RE110.03.01)
- Three-phase measurement of current and voltage: 3x400 V/5 A
- Two Digital inputs
- Two relay outputs
- Operating Voltage: 220 VAC
- Max Current: 5A
- Max. measurement values
- Voltage P-P: 690 V
- Current: 5 A
- Fault tolerances
- Voltage 0.2%, Current 0.2%
- Apparent power 0.5%, Active power 0.2%, Reactive power 1%
- Active energy Class 0.2, Reactive energy Class 2
- Operating voltage
Metering Panel (RE110.03.02)
- Digital Current Meter:
- Two independent Channels.
- Each channel has two Ranges (5A peak Range – Accuracy +-1% / 10A peak Range – Accuracy +-1%),
- Channels protected against over current
- Digital Voltage Meter:
- Two independent Channels,
- Each channel has a selectable Range of (60V peak Range – Accuracy +-1% / 300V peak Range – Accuracy +-1% / 600V peak Range – Accuracy +-1%),
- Channels protected against over voltage
- Communication:
- RS485
- Graphical Display:
- Touch LCD 5inch, 800x480 pixel display
- Monitoring 2 voltage channels and 2 current channels,
- Configuring Measurement Ranges
- Power Supply:
MPPT Solar / Wind Charge Controller (RE110.03.03)
- This module controller is advanced maximum power point tracking (MPPT) charging technology for off-grid photovoltaic systems.it is mainly used in the field of security monitoring, RV, and household system, etc.
- Technical Data
- Voltage:12V/24V Auto
- Current:20A
- Max. PV input power:300W/12V,700W/24V
- Communication:RS232
Battery Accumulator (RE110.03.04)
- This Module is designed to enable students to charge and discharge batteries according to the experiment needs.
- The module also obtains the ability to connect Remotely, so that students can connect and disconnect this module remotely through our software.
- Technical Data
- Battery Voltage: 12V
- Battery Capacity: 50 A/H
3-phase Rectifier Module (RE110.03.05)
- This module is used to convert three-phase alternating current to direct current. It has three inputs terminals for AC voltage and two output terminals for DC voltage.
- Technical Data
- 3 phase Input Voltage: up to 32 V AC
- 3 phase Input current: up to 20 A AC
- Rated output power: 1.2 Kw
- Rated DC voltage output: 0 to 56 V DC
DC Load (RE110.03.06)
- This Module is designed to simulate a real DC Load, using two different types of lamps.
- The module consists of two Halogen lamp and two LED lamps.
- This module enables students to access different load wattages on experiments.
- Technical Data
- Halogen Lamp
- Voltage Required: 12V
- Watt: 50 W
- LED Lamp
- Voltage Required: 12V
- Watt: 5 W
Lamp module (RE110.03.07)
- This Module is designed to simulate a real AC Load
- Technical Data
- Voltage Required: 220V AC