This laboratory is designed to allow students to learn about DC and AC machines and transformers.The Laboratory is supplied with Different type of components such as motors, load units, measuring units and universal power supplies.The trainees can perform various types of experiments by connecting set of cable to a 4mm safety banana socket.The laboratory includes interactive softwares which can display measured units and plot the results.
-
- Universal Measuring Device (ML300.01.02)
-
Technical Data
-
True RMS measurements, 0.2% accuracy
-
Harmonic distortion display (31 harmonics)
-
Max demand display
-
User-configurable display screen
-
Sealed front panel (ip54)
-
RS-485 interface
-
Measurements:
-
Phase to phase voltages: u12-u23- u31-uavg
-
Phase to neutral voltages: v1-v2-v3- vavg
-
Phase currents: i1-i2-i3-in-iavg-itot
-
Active power: p1-p2-p3-Σp
-
Reactive power: q1-q2-q3-Σq
-
Apparent power: s1-s2-s3-Σs
-
Power factor: cos1-cos2-cos3-Σcos
-
Active power counters: pc1-pc2
-
Reactive power counters: qc1-qc2
-
User counters: usr1-usr2-usr3-usr4
-
2...31 harmonics of any voltage or current
-
Input voltage: 0-300VAC ph-N
-
Variable Frequency Drive (VFD) (ML300.01.03)
-
Universal Switch Unit (ML300.01.04)
-
Squirrel cage motor fault simulator (ML300.01.05)
-
The ends of the stator windings are connected to a series of switchesthat, when activated, simulate common faults on the motor.
-
The instructor activates the switches to simulate faults and assigns to the student the task of analyzing and explaining them.
-
When all switches are in their normal position, the motor behaves as a typical cage motor.
-
Technical Data:
-
Three-phase Transformer (ML300.01.06)
-
Scott-T Transformer (ML300.01.07)
- Regulating transformer, exciter 0-200V (ML300.01.08)
- Variable isolating transformer as exciter 0-200 V for field excitation of DC, synchronous and multi-function machines.
- Output voltage: 0...200 V, 2 A AC/DC, 0...30 V, 10 A AC/DC
- Voltage supply: 230 V, 50 Hz via 2mm mains cable or 4mm sockets.
- Exciter voltage controller with de-excitation (ML300.01.09)
- The exciter voltage controller is used in experiments involving synchronization.
- The de-excitation switch is used in generator protection measures and is responsible for the disconnection of the generator from the grid and its de-excitation in the event of a fault.
- Technical Data:
- Output: DC 200 V/2 A
- Output: DC 24 V/2.731 A
- 2X push buttons for switching the DC voltage on and off
- Inputs and outputs: 4-mm safety sockets
- Power supply: 230 V, 50/60 Hz
- Synchronization unit (ML300.01.10)
- The Synchronization Unit consists of:
- Three Pilot indicators operating voltage (Lamps): 500 VAC
- Zero voltmeter 0….400V
- Frequency, voltage, and current measuring devices for the generator bus and the mains to maintain the manual synchronization conditions to function
- Double frequency measurement: FROM 47 TO 53 HZ
- Double voltmeter measurement: 0 TO 500 V
- The synchronizer (Digital synchronoscope) display is used to display voltage and phase angles between the generator and the power supply
- Technical Data:
- Generator voltage: 300 V-AC max.(Ph-N)
- Generator frequency: 0-100 Hz.
- Busbar voltage: 300 V-AC max. (Ph-N)
- Busbar frequency: 50/60 Hz.
- Digital inputs: 0 - 30 V-DC DC
- Supply Range: 9.0 to 33.0 V-DC
- Synchronization switch
- Operating voltage: 400V
- Regulated high DC voltage power supply (ML300.02)
- Technical Data
- Power: 1400W
- Voltage: 0~500VDC
- Current: 0~4ADC
- Overvoltage, overcurrent, overtemperature, and overpower protection
- Constant voltage (CV) and constant current (CC) operations
- Adjustable OVP & OCP range, OPP fixed 110%.
- Accuracy: ±(3% FS+1 digit)
- Software Code: (ML300.03)
- Electrical machines & transformers trainer interactive software with remote learning facility.
- Measurements and graphics can be saved within the experiment instructions by means of drag and drop. The software can detect the machine under test and display its nameplate.
- 300 Watts Machines 3000 RPM Code: (ML300.04) (Not included)
-
- The winding ends are connected to 4 mm safety sockets in a metal housing on top of which a clear electrical drawing shows the internal Logic of the machine.
- The students can therefore easily understand operation and winding connections.
- Include an electronic nameplate for machine parameters for automatic machine identification.
- Relevant machine data is automatically uploaded
- Pre-setting of scaling in the software
- DC. Brake Test Bench (ML300.04.01)
- A full test bench used to perform experiments of loading on different machines to determine the characteristics of any motor, like torque-speed characteristics.
- The test bench is powered from the main trainer through power cable and protected with on/off, emergency switches.
- The trainer is connected to the main software through a RS-485 Connection via 4mm safety bananas
- The trainer is capable of automatically identify the machine under test via audio socket cable.
- The Test Bench consists of :
- Resistive potentiometer to apply electrical load on the machine under test
- Digital meter to show the speed of the shaft
- Braking DC Generator:
- Nominal shaft speed: 3000 rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Tacho-Generator :
- 26V/1000RPM
- Rated Speed: 3000RPM
- Load Cell:
- Three-Phase Asynchronous Squirrel Cage Motor (ML300.04.02)
- Nominal shaft speed: 3000rpm
- Rated output power: 100W
- Rated input voltage: 220VAC /380VAC
- Rated operating frequency: 50Hz
- Three-Phase Slip Ring Motor (ML300.04.03)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated o perating frequency: 50Hz
- Three-Phase Synchronous Machine (ML300.04.04)
- Nominal shaft speed: 3000rpm
- Rated output power: 200W
- Rated input voltage: 75VAC / 140VAC
- Rated operating frequency: 50Hz
- Three-Phase Double Speed Induction Motor (ML300.04.05)
- Nominal shaft speed: 3000/1500rpm
- Rated input voltage: 380VAC
- Rated operating frequency: 50Hz
- Single-Phase Universal Motor (ML300.04.06)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC/VDC
- Rated operating frequency: 50Hz
- Single-Phase Capacitor-Start Motor (ML300.04.07)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC
- Rated operating frequency: 50Hz
- DC Compound Machine (ML300.04.08)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- DC Series Machine (ML300.04.09)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated Input Voltage: 220VDC
- DC Shunt/Separately Excited Machine (ML300.04.10)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- DC Permanent Magnet Machine (ML300.04.11)
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated Input Voltage: 220VDC
- Braking DC Generator (ML300.04.12)
- Nominal shaft speed: 3000rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Magnetic Powder Brake (ML300.04.13)
- Rated braking power: 800W
- Nominal input voltage: 0 - 24VDC
- Three-Phase Squirrel Cage Induction Motor Cutaway (ML300.04.14)
- Nominal power approx.: 0,25 kW
- Nominal speed approx: 1400 rpm
- Nominal input voltage volts (Δ/y): 230/400V
- Frequency: 50 Hz
- Additional modules for 300-watt 3000 rpm machines (ML300.04.15)
- Motor Protection Switch
- Power circuit breaker including thermal overload trip and overcurrent trip
- 1X Motor protection switch, 0.7...1A
- Contact rating: 500V, 10A
- Resistive Loads
- Universal Resistor Bank
- Overview
- Contains nine power resistors arranged in three banks ( Three resistors in each bank )
- Resistors of each bank are arranged in parallel connection by toggle switch for each resistor to obtain multiple values.
- Three resistor banks can be used separately in 3-phase circuits or can be connected together in single phase circuits
- Specifications:
- Three Banks (Three Resistors for each bank)
- Resistor Values : 0.8K / 1.6K / 3.2K Ohms
- Universal Rheostat
-
- Overview
- Contains three rheostats in series with three fixed power resistors arranged in three branches.
- Three branches can be used separately in 3-phase circuits or can be connected together in single phase circuits.
- Specifications:
- Branch Values : 500 to 900 Ohms
- Maximum Voltage : 220 V AC/DC
- Rheostat for field regulation
- Range of resistance value: 0 - 2.2Kohm
- Power capacity: 25W
- Inductive Load
- Overview
- Contains nine iron core power inductors arranged in three banks (Three inductors in each bank)
- Inductors of each bank are arranged in parallel connection by toggle switch for each inductor to obtain multiple values.
- Three inductor banks can be used separately in 3 phase circuits or can be connected together in single phase circuits
- Specifications:
- Three Banks (Three Inductors for each bank)
- Inductor Values : 2.5 / 5 / 10 H
- Maximum Voltage : 220 V AC
- Capacitive Load
- Overview:
- Contains nine capacitors arranged in three banks ( Three capacitors in each bank )
- Capacitors of each bank are arranged in parallel connection by toggle switch for each capacitor to obtain multiple values
- Three capacitive banks can be used separately in 3 phase circuits or can be connected together in single phase circuits
- Specifications:
- Three Banks (Three Capacitors for each bank)
- Capacitor Values : 1 / 2 / 4 uF
- Maximum Voltage : 450 V AC/DC
- 300 Watts Machines 1500 RPM Code: (ML300.05) (Not included)
- The windings ends are connected to 4 mm safety sockets in a metal housing on top of which a clear electrical drawing shows the internal Logic of the machine.
- The students can therefore easily understand operation and windings connections.
- Include electronic name plate for machine parameters for automatic machine identification.
- Relevant machine data is automatically uploaded
- Pre-setting of scaling in the software
- DC. Brake Test Bench (ML300.05.01)
- A full test bench used to perform experiments of loading on different machines to determine the characteristics of any motor like torque-speed characteristics.
- The test bench is powered from the main trainer through power cable and protected with on/off, emergency switches.
- The trainer is connected to the main software through a RS-485 Connection via 4mm safety bananas
- The trainer is capable of automatically identify the machine under test via audio socket cable.
- The Test Bench consists of :
- Resistive potentiometer to apply electrical load on the machine under test
- Digital meter to show the speed of the shaft
- Braking DC Generator :
- Nominal shaft speed: 1500 rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Tacho-Generator :
- 26V/1000RPM
- rated Speed: 3000RPM
- Load Cell:
- 10Kg, 2mV/V
- Three-Phase Asynchronous Squirrel Cage Motor (ML300.05.02)
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Three-Phase Slip Ring Motor (ML300.05.03)
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Three-Phase Synchronous Machine (ML300.05.04)
- Nominal shaft speed: 1500rpm
- Rated output power: 220W
- Rated input voltage: 83/145VAC
- Rated operating frequency: 50Hz
- Three-Phase Double Speed Induction Motor (ML300.05.05)
- Nominal shaft speed: 3000/1500rpm
- Rated input voltage: 380VAC
- Rated operating frequency: 50Hz
- Single-Phase Capacitor-Start Motor (ML300.05.06)
- Nominal shaft speed: 1500 rpm
- Rated output power: 300W
- Rated input voltage: 220VAC
- Rated operating frequency: 50Hz
- DC Compound Machine (ML300.05.07)
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- DC Series Machine (ML300.05.08)
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated Input voltage: 220VDC
- DC Shunt/Separately Excited Machine (ML300.05.09)
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- Permanent Magnet Dc Machine (ML300.05.10)
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated Input voltage: 220VDC
- Braking DC Generator (ML300.05.11)
- Nominal shaft speed: 1500rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Magnetic Powder Brake (ML300.05.12)
- Nominal shaft speed: 1500rpm
- Rated braking power: 300W
- Nominal Input voltage: 0- 24VDC
- Three-Phase Squirrel Cage Induction Motor Cutaway (ML300.05.13)
- Nominal power approx.: 0,25 kW
- Nominal speed approx. 1400 rpm
- Nominal input voltage volts (Δ/y) 230/400V
- Frequency: 50 Hz
- Additional modules for 300 watt 1500 rpm machines (ML300.05.14)
- Motor Protection Switch
- Power circuit breaker including thermal overload trip and overcurrent trip
- 1X Motor protection switch, 0.7...1A
- Contact rating: 500V, 10A
- Resistive Loads
- Universal Resistor Bank
- Overview
- Contains nine power resistors arranged in three banks ( Three resistors in each bank )
- Resistors of each bank are arranged in parallel connection by toggle switch for each resistor to obtain multiple values.
- Three resistor banks can be used separately in 3-phase circuits or can be connected together in single phase circuits
- Specifications:
- Three Banks (Three Resistors for each bank)
- Resistor Values : 0.8K / 1.6K / 3.2K Ohms
- Maximum Voltage : 220 V AC/DC
- Universal Rheostat
- Overview
- Contains three rheostats in series with three fixed power resistors arranged in three branches.
- Three branches can be used separately in 3-phase circuits or can be connected together in single phase circuits.
- Specifications:
- Branch Values : 500 to 900 Ohms
- Maximum Voltage : 220 V AC/DC
- Rheostat for field regulation
- Range of resistance value: 0 - 2.2Kohm
- Power capacity: 25W
- Inductive Load
- Overview:
- Contains nine iron core power inductors arranged in three banks (Three inductors in each bank)
- Inductors of each bank are arranged in parallel connection by toggle switch for each inductor to obtain multiple values.
- Three inductor banks can be used separately in 3 phase circuits or can be connected together in single phase circuits
- Specifications:
- Three Banks (Three Inductors for each bank)
- Inductor Values : 2.5 / 5 / 10 H
- Maximum Voltage : 220 V AC
- Capacitive Load
- Overview:
- Contains nine capacitors arranged in three banks ( Three capacitors in each bank )
- Capacitors of each bank are arranged in parallel connection by toggle switch for each capacitor to obtain multiple values
- Three capacitive banks can be used separately in 3 phase circuits or can be connected together in single phase circuits
- Specifications:
- Three Banks (Three Capacitors for each bank)
- Capacitor Values : 1 / 2 / 4 uF
- Maximum Voltage: 450 V AC/DC
- Servo machine test Stand (Not Included) Code: (ML300.06)
- The servo-machine test bench is a complete testing system for examining electrical machines and drives. It consists of a digital controller, a brake and the software. The system combines state-of-the-art technology with ease of operation.
- The system also allows manual and automated synchronization to be carried out.
- The controller has the following features:
- Dynamic and static four-quadrant operation
- Selectable operating modes/machine models (torque control, speed control.
- Interface for reading electronic nameplates EDD of the machines under test
- Integrated galvanically isolated amplifier for voltage and current measurement
- Colour display
- Four-quadrant monitor
- Isolated USB interface
- Connection voltage: 400V, 45...65Hz
- The motor and sensor leads are connected via polarity-safe plugs. The machine has thermal monitoring and, in conjunction with the controller, it constitutes a driving and braking system that is free of drift and requires no calibration.
- Technical Data:
- Maximum speed: 3000 RPM
- Maximum Voltage: 3~, 220V
- Maximum Motor Current: 9.5A
- Motor Maximum Capacity : 2.2 kw
- Software features
- Measurement, calculation & display of mechanical & electrical variables (Speed, torque, mechanical power output, current, voltage, active, apparent and reactive power, efficiency, power factor).
- Reading Electronic nameplates of the machines under test.
- Simultaneous display of measured and calculated values (e.g. instant display of efficiency)
- Measurement of voltage and current (including RMS values even for non-sinusoidal waveforms)
Speed or torque-controlled operation
- Recording of variables over time
- Programming of limiting values of speed or torque to prevent inappropriate loading of the machine under test.
- Operation in all four quadrants (display of generated torque)
- Export of graphics & measurements
- Special Machines (ML300.06)
- The windings ends are connected to 4 mm safety sockets in a metal housing on top of which a clear electrical drawing shows the internal Logic of the machine.
- The students can therefore easily understand operation and windings connections.
- Include electronic name plate for machine parameters for automatic machine identification.
- Relevant machine data is automatically uploaded
- Pre-setting of scaling in the software
- A full test bench used to perform experiments of loading on different machines to determine the characteristics of any motor like torque-speed characteristics.
- The test bench is powered from the main trainer through power cable and protected with on/off, emergency switches.
- The trainer is connected to the main software through a RS-485 Connection via 4mm safety bananas
- The trainer is capable of automatically identify the machine under test via audio socket cable.
- The Test Bench consists of :
- Resistive potentiometer to apply electrical load on the machine under test
- Digital meter to show the speed of the shaft
- Braking DC Generator:
- Nominal shaft speed: 3000 rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Tacho-Generator :
- 20V/1000RPM
- rated Speed: 3000RPM
- Load Cell:
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000/1500rpm
- Rated output power: 300W/220W
- Rated input voltage: 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC/VDC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated input voltage: 220VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated Input Voltage: 220VDC
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- Nominal shaft speed: 3000rpm
- Rated output power: 300W
- Rated Input Voltage: 220VDC
- Nominal shaft speed: 3000rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Nominal shaft speed: 3000rpm
- Rated braking power: 300W
- Nominal input voltage: 0- 90VDC
- Nominal power approx.: 0,25 kW
- Nominal speed approx: 1400 rpm
- Nominal input voltage volts (Δ/y): 230/400V
- Frequency: 50 Hz
- Motor Protection Switch
- Power circuit breaker including thermal overload trip and overcurrent trip
- 1X Motor protection switch, 0.7...1A
- Contact rating: 500V, 10A
- Resistive Load
- Resistive load for DC generator (with rotary switching)
- Rated operating voltage: 220VDC
- Number of steps: 7
- Loading capability at first step: 75W
- Loading capability at last step: 300W
- Resistive load for DC generator (with continuous variation)
- Rated operating voltage: 220VDC
- Range of resistance value: 162ohm (min) to 362ohm (max)
- Loading capability at max resistance value: 133W
- Loading capability at minimum resistance: 300W
- Resistive load for 3-phase synchronous generator (with rotary switching)
- Rated operating voltage: 220VAC / 380VAC
- Number of steps per phase: 5
- Minimum loading capability per phase: 50W
- Maximum loading capability per phase: 100W
- Resistive load for 3-phase synchronous generator (with continuous variation)
- Rated operating voltage: 220VAC / 380VAC
- Range of resistance value per phase: 485ohm (min) to 0.97Kohm (max)
- Minimum loading capability per phase: 50W
- Maximum loading capability per phase: 100W
- Rheostat for field regulation
- Range of resistance value: 0 -2.2Kohm
- Power capacity: 25W
- Inductive Load
- Inductive load for 3-phase synchronous generator (with rotary switching)
- Rated operating voltage: 220VAC / 380VAC
- Number of steps per phase: 7
- Minimum loading capability per phase: 50VAR
- Maximum loading capability per phase: 100VAR
- Capacitive Load
- Capacitive load for 3-phase synchronous generator (with rotary switching)
- Rated operating voltage: 220VAC / 380VAC
- Number of steps per phase: 5
- Minimum loading capability per phase: 50VAR
- Maximum loading capability per phase: 100VAR
- The windings ends are connected to 4 mm safety sockets in a metal housing on top of which a clear electrical drawing shows the internal Logic of the machine.
- The students can therefore easily understand operation and windings connections.
- Include electronic name plate for machine parameters for automatic machine identification.
- Relevant machine data is automatically uploaded
- Pre-setting of scaling in the software
- A full test bench used to perform experiments of loading on different machines to determine the characteristics of any motor like torque-speed characteristics.
- The test bench is powered from the main trainer through power cable and protected with on/off, emergency switches.
- The trainer is connected to the main software through a RS-485 Connection via 4mm safety bananas
- The trainer is capable of automatically identify the machine under test via audio socket cable.
- The Test Bench consists of :
- Resistive potentiometer to apply electrical load on the machine under test
- Digital meter to show the speed of the shaft
- Braking DC Generator :
- Nominal shaft speed: 1500 rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Tacho-Generator :
- 20V/1000RPM
- rated Speed: 3000RPM
- Load Cell:
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated input voltage: 220VAC / 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 3000/1500rpm
- Rated output power: 300/220W
- Rated input voltage: 380VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 1500 rpm
- Rated output power: 300W
- Rated input voltage: 220VAC
- Rated operating frequency: 50Hz
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated Input voltage: 220VDC
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated armature voltage: 220VDC
- Rated field voltage: 220VDC
- Nominal shaft speed: 1500rpm
- Rated output power: 300W
- Rated Input voltage: 220VDC
- Nominal shaft speed: 1500rpm
- Rated braking power: 300W
- Rated generated output voltage: 220VDC
- Nominal excitation voltage: 220VDC
- Nominal shaft speed: 1500rpm
- Rated braking power: 300W
- Nominal Input voltage: 0- 90VDC
- Nominal shaft speed: 3000rpm
- Rated braking power: 300W
- Nominal input voltage: 0- 90VDC
- Nominal power approx.: 0,25 kW
- Nominal speed approx: 1400 rpm
- Nominal input voltage volts (Δ/y): 230/400V
- Frequency: 50 Hz
- Motor Protection Switch
- Power circuit breaker including thermal overload trip and overcurrent trip
- 1X Motor protection switch, 0.7...1A
- Contact rating: 500V, 10A
- Resistive Load:
- Resistive load for DC generator (with rotary switching)
- Rated operating voltage: 220VDC
- Number of steps: 7
- Loading capability at first step: 75W
- Loading capability at last step: 300W
- Resistive load for DC generator (with continuous variation)
- Rated operating voltage: 220VDC
- Range of resistance value: 162ohm (min) to 362ohm (max)
- Loading capability at max resistance value: 133W
- Loading capability at minimum resistance: 300W
- Resistive load for 3-phase synchronous generator (with rotary switching)
- Rated operating voltage: 220VAC / 380VAC
- Number of steps per phase: 5
- Minimum loading capability per phase: 50W
- Maximum loading capability per phase: 100W
- Resistive load for 3-phase synchronous generator (with continuous variation)
- Rated operating voltage: 220VAC / 380VAC
- Range of resistance value per phase: 485ohm (min) to 0.97Kohm (max)
- Minimum loading capability per phase: 50W
- Maximum loading capability per phase: 100W
- Rheostat for field regulation
- Range of resistance value: 0 -2.2Kohm
- Power capacity: 25W
- Inductive Load
- Inductive load for 3-phase synchronous generator (with rotary switching)
- Rated operating voltage: 220VAC / 380VAC
- Number of steps per phase: 7
- Minimum loading capability per phase: 50VAR
- Maximum loading capability per phase: 100VAR
- Capacitive Load
- Capacitive load for 3-phase synchronous generator (with rotary switching)
- Rated operating voltage: 220VAC / 380VAC
- Number of steps per phase: 5
- Minimum loading capability per phase: 50VAR
- Maximum loading capability per phase: 100VAR
- The servo-machine test bench is a complete testing system for examining electrical machines and drives. It consists of a digital controller, a brake and the software. The system combines state-of-the-art technology with ease of operation.
- The system also allows manual and automated synchronization to be carried out.
- The controller has the following features:
- Dynamic and static four-quadrant operation
- Selectable operating modes/machine models (torque control, speed control.
- Interface for reading electronic nameplates EDD of the machines under test
- Integrated galvanically isolated amplifier for voltage and current measurement
- Colour touch display
- Four-quadrant monitor
- Isolated USB interface
- Connection voltage: 400V, 45...65Hz
- The motor and sensor leads are connected via polarity-safe plugs. The machine has thermal monitoring and, in conjunction with the controller, it constitutes a driving and braking system that is free of drift and requires no calibration.
- Maximum speed: 3000 RPM
- Maximum Voltage: 3~, 220V
- Maximum Current: 12.75A
- Motor Capacity : 3.5 kw
- Resolver resolution: 3000 pulses/revolution
- Software features
- Measurement, calculation and display of mechanical and electrical variables (Speed, torque, mechanical power output, current, voltage, active, apparent and reactive power, efficiency, power factor).
- Reading Electronic nameplates of the machines under test.
- Simultaneous display of measured and calculated values (e.g. instant display of efficiency)
- Measurement of voltage and current (including RMS values even for non-sinusoidal waveforms)
- Speed or torque-controlled operation
- Recording of variables over time
- Programming of limiting values of speed or torque to prevent inappropriate loading of the machine under test.
- Operation in all four quadrants (display of generated torque)
- Export of graphics and measurements