Machine & Drive Lab Main Frame can operate both AC and DC machines and transformers up to 3 KW, it is designed to be combat and can be expanded to enable the trainees to add up to 10 modules, by using a set of interchangeable modules the trainees can execute different experiments.
- The Unit contains a vertical panel divided into two sections a control section and an aluminum panel section used for fixing the experimental modules. In addition to horizontal work bench.
- The control panel section is also provided with circuit breakers to protect the unit, overload LED that lights up when the unit is overloaded, and emergency button and On/Off switch to operate the unit
- The control panel includes a knobs to control the values of AC and DC voltage power supplies.
- The training system can supply machines with power up to 3 KW.
- Main Frame Code: (ML-100.1)
- Universal power supply (ML-100.1.1)
- The Supply Is designed for use with electrical machines
- Three-phase fixed power supply.
- Output voltage: 3x 400V, 50 Hz
- Short circuit protection with 4-pole MCB up to 25A
- Undervoltage Trip
- Motor protection switch adjustable from 6.3 to 25A
- Output from 4mm banana safety sockets L1 ,L2,L3 ,N AND PE
- 2x Three-phase variable power supply.
- Current: up to 6 A
- Voltage: 0…..400V, 50Hz
- Short circuit protection
- overload protection
- output from 4mm banana safety sockets L1, L2, L3, N and PE.
- DC fixed power supply
- Short circuit protection
- Output current: 2A
- Output voltage: 220V
- Output power 440W
- Output from 4mm banana safety sockets +VE, -VE
- 2x Variable DC power supply
- First Supply:
- Short circuit protection
- Output current: up to 12A
- Output voltage: 0….250V
- Maximum output power: 3000W
- Output from 4mm banana safety sockets +VE, -VE
- Second supply:
- Short circuit protection
- Output current up to 2A
- Output voltage 0…250V
- Maximum output power 500W
- Output from 4mm banana safety sockets +VE, -VE
- Regulated high voltage power supply (ML-100.1.2)
- Power: 1400W
- Voltage: 0~500V
- Current: 0~4A
- Over voltage, over current, over temperature and over power protections
- Coarse and Fine control for voltage and current
- Constant voltage (CV) and constant current (CC) operations
- Adjustable OVP & OCP range, OPP fixed 110% of Max. power
- Display
- Voltmeter: 4 digits LED display
- Voltage resolution: 0.000-9.999V; 00.00-99.99V; 000.0-999.9V
- Current resolution: 0.000-9.999A; 00.00-99.99A; 000.0-999.9A
- Accuracy: ±(1% FS+1 digit)
- Main Modules Kit Code: (ML-100.2)
- Multi-range dc voltmeter, ammeter module (ML-100.2.1)
- Input voltage: 220V, 50Hz on 4 mm safety banana socket
- RS-485 interface
- Range 0 to 5 A
- 0 to 500 VDC
- Fuse protection
- Multi-Range ac voltmeter, ammeter module (ML-100.2.2)
- Input voltage 220V, 50Hz on 4 mm safety banana socket
- RS-485 interface
- Range 0 to 5 A
- 0 to 500 VAC
- Fuse protection
- Torque meter (ML-100.2.3)
- 220 V, 50 Hz Supply from 4 mm banana socket
- output serial communication RS485 via 4mm safety bannanas
- Input for load cell connection via 9 pin sub-D connector
- Cut-Off Switch Module 4-Pole (ML-100.2.4)
- Switch position: 0 - 1 (rotary switch)
- Contact rating: 690V, 12A max.
- Inputs/outputs: 4mm safety sockets
- Contactors and switching circuits training set (ML-100.2.5)
- With this set, basic contactor circuits can be assembled that include protective and operating elements.
- Sub-assemblies:
- 4 X Latched push-button switches, 1 NO/1 NC
- 4X Latched push-button switches, 1 NO/1 NC, with White indicator lamp
- 1X Set of Four indicator lamps, green
- 3x Main contactors, 3-pole
- 3x Auxiliary contactors, 2 NO/2 NC
- 1 Remote pulse switch, 1 change-over contact
- 1 X Time-delay relay, delayed drop-out, 1.5....30s
- 1X Time-delay relay, delayed pull-on, 1.5....30s
- 1 X Line circuit breaker, 3-pole
- 1X Line circuit breaker, single-pole
- 4 X red push button 1NO/1NC Contact Emergency Stop Push Button 2NC Contacts
- Technical Data:
- Nominal voltage: 230/400V, max. 690V
- Control voltage: 230V
- Maximum current: 16A