We Make The Difference
Machine & Drive Lab Supply Unit
(ML-100)

Machine & Drive Lab Main Frame can operate both AC and DC machines and transformers up to 3 KW, it is designed to be combat and can be expanded to enable the trainees to add up to 10 modules, by using a set of interchangeable modules the trainees can execute different experiments.

  • The Unit contains a vertical panel divided into two sections a control section and an aluminum panel section used for fixing the experimental modules. In addition to horizontal work bench.
  • The control panel section is also provided with circuit breakers to protect the unit, overload LED that lights up when the unit is overloaded, and emergency button and On/Off switch to operate the unit
  • The control panel includes a knobs to control the values of AC and DC voltage power supplies.
  • The training system can supply machines with power up to 3 KW.
  • Main Frame Code: (ML-100.1)
    • Universal power supply (ML-100.1.1)
      • The Supply Is designed for use with electrical machines
        • Three-phase fixed power supply.
          • Output voltage: 3x 400V, 50 Hz
          • Short circuit protection with 4-pole MCB up to 25A
          • Undervoltage Trip
          • Motor protection switch adjustable from 6.3 to 25A
          • Output from 4mm banana safety sockets L1 ,L2,L3 ,N AND PE
        • 2x Three-phase variable power supply.
          • Current: up to 6 A
          • Voltage: 0…..400V, 50Hz
          • Short circuit protection
          • overload protection
          • output from 4mm banana safety sockets L1, L2, L3, N and PE.
        • DC fixed power supply
          • Short circuit protection
          • Output current: 2A
          • Output voltage: 220V
          • Output power 440W
          • Output from 4mm banana safety sockets +VE, -VE
        • 2x Variable DC power supply
          • First Supply:
            • Short circuit protection
            • Output current: up to 12A
            • Output voltage: 0….250V
            • Maximum output power: 3000W
            • Output from 4mm banana safety sockets +VE, -VE
          • Second supply:
            • Short circuit protection
            • Output current up to 2A
            • Output voltage 0…250V
            • Maximum output power 500W
            • Output from 4mm banana safety sockets +VE, -VE
    • Regulated high voltage power supply (ML-100.1.2)
      • Power: 1400W
      • Voltage: 0~500V
      • Current: 0~4A
      • Over voltage, over current, over temperature and over power protections
      • Coarse and Fine control for voltage and current
      • Constant voltage (CV) and constant current (CC) operations
      • Adjustable OVP & OCP range, OPP fixed 110% of Max. power
      • Display
        • Voltmeter: 4 digits LED display
        • Voltage resolution: 0.000-9.999V; 00.00-99.99V; 000.0-999.9V
        • Current resolution: 0.000-9.999A; 00.00-99.99A; 000.0-999.9A
        • Accuracy: ±(1% FS+1 digit)
  • Main Modules Kit Code: (ML-100.2)
    • Multi-range dc voltmeter, ammeter module (ML-100.2.1)
      • Input voltage: 220V, 50Hz on 4 mm safety banana socket
      • RS-485 interface
      • Range 0 to 5 A
      • 0 to 500 VDC
      • Fuse protection
    • Multi-Range ac voltmeter, ammeter module (ML-100.2.2)
      • Input voltage 220V, 50Hz on 4 mm safety banana socket
      • RS-485 interface
      • Range 0 to 5 A
      • 0 to 500 VAC
      • Fuse protection
    • Torque meter (ML-100.2.3)
      • 220 V, 50 Hz Supply from 4 mm banana socket
      • output serial communication RS485 via 4mm safety bannanas
      • Input for load cell connection via 9 pin sub-D connector
    • Cut-Off Switch Module 4-Pole (ML-100.2.4)
      • Switch position: 0 - 1 (rotary switch)
      • Contact rating: 690V, 12A max.
      • Inputs/outputs: 4mm safety sockets
    • Contactors and switching circuits training set (ML-100.2.5)
      • With this set, basic contactor circuits can be assembled that include protective and operating elements.
      • Sub-assemblies:
        • 4 X Latched push-button switches, 1 NO/1 NC
        • 4X Latched push-button switches, 1 NO/1 NC, with White indicator lamp
        • 1X Set of Four indicator lamps, green
        • 3x Main contactors, 3-pole
        • 3x Auxiliary contactors, 2 NO/2 NC
        • 1 Remote pulse switch, 1 change-over contact
        • 1 X Time-delay relay, delayed drop-out, 1.5....30s
        • 1X Time-delay relay, delayed pull-on, 1.5....30s
        • 1 X Line circuit breaker, 3-pole
        • 1X Line circuit breaker, single-pole
        • 4 X red push button 1NO/1NC Contact Emergency Stop Push Button 2NC Contacts
      • Technical Data:
        • Nominal voltage: 230/400V, max. 690V
        • Control voltage: 230V
        • Maximum current: 16A